Prospects of electrosleep therapy devices for long-distance drivers

Tytuł:
Prospects of electrosleep therapy devices for long-distance drivers
Autorzy:
Kernytskyy, Ivan
Storchun, Yevhen
Yakovenko, Yevheniia
Horbay, Orest
Humenuyk, Ruslan
Sholudko, Yaroslav
Data publikacji:
2020
Wydawca:
Szkoła Główna Gospodarstwa Wiejskiego w Warszawie. Wydawnictwo Szkoły Głównej Gospodarstwa Wiejskiego w Warszawie
Tematy:
encephalogram
biorhythm
correlation coefficient
impulse signal
electrosleep therapy devices
long-distance driver
Źródło:
Scientific Review Engineering and Environmental Sciences; 2020, 29, 4; 454-460
1732-9353
Język:
angielski
Prawa:
CC BY-NC: Creative Commons Uznanie autorstwa - Użycie niekomercyjne 3.0 PL
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
Accomulated exhaustion is a fairly common problem for long-distance truck and bus drivers on international routes. In case of uncompensated exhaustion, the driver is unable to overcome the resulting attention violations with will effort, which increases the probability of errors and accidents. The last claim is confirmed by the increase in the number of incidents after 7 h and especially 10 h of work. To overcome this problem, it is necessary to stop and fall asleep for a short time. Recovery comes in about 10–15 min of relaxation. The source of stimulation of the brain is weak impulse current, which causes sleep of varying depth and duration. Clinical studies have shown that the strongest impact is on pulses with a duration of approximately 0.3– –0.5 ms and a frequency of repetition ranging from 0.5–2 to 80–100 Hz. Current levels are typically between 50 and 5 mA. Transcranial electrotherapy is considered to stimulate endorphin production and affect the hypothalamus, causing changes in neurohormonal regulatory mechanisms and reticular formation of the brain stem. The reticular formation is involved in many behavioral reactions and has a significant impact on body functioning and thought processes. The aim of this work was to determine correlation between human brain biorhythms and electrosleep device signal by calculating mutual correlation. For this purpose, the model in MATLAB Simulink environment was developed. The encephalogram was processed using the EEGLAB tool to remove artifacts. A model in the MATLAB Simulink environment was developed to evaluate the effect of the signal characteristics of electrosleep therapy devices on brain biorhythms, with the help of which correlation coefficients were calculated.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies

Prześlij opinię

Twoje opinie są dla nas bardzo ważne i mogą być niezwykle pomocne w pokazaniu nam, gdzie możemy dokonać ulepszeń. Bylibyśmy bardzo wdzięczni za poświęcenie kilku chwil na wypełnienie krótkiego formularza.

Formularz